Showa Sokki MRU Load Cell

Features:  

*Ultra-miniature.

 

Standard Specifications

Rated Capacities  
Maximum Overload 120% R.C.
Rated Output  1mV/V +/-20% 
Non-Linearity 2.0% R.O. 
Hysteresis  2.0% R.O.
Repeatability  2.0% R.O.
Recommended Excitation Voltage  2V
Maximum Excitation Voltage 3V
Input & Output Resistance 120 Ohms
Compensated Temperature Range 00C to 600C
Maximum Temperature Range -100C to 800
Thermal Zero Shift 0.2% R.O./ 0C
Thermal Sensitivity Shift 0.03%/ 0C
Connecting Cable/Connector 2mm diameter, 4-conductor shielded cable, 2m long, with peeled tip.
Model
Rated Capacity
Proper Frequency
Weight

MRU-200N

200N

41kHz

3g

MRU-500N

500N

66kHz

3g

MRU-1kN

1kN

101kHz

3g